Local Control (Local Mode) R&S SU 4200
3.21 6125.0226.12.01
3.4.3.3 Standard Operating Display
Standard oper ating displ ay\Standard o perating di splay "Radio ".doc
3.4.3.3.1 Standard Operating Display
Display parameter
During operation, the LCD indicates the most important settings and status
messages.
R&S SU 4200
example
S U 4 2 0 0
2
1
:
0
4
:
1
3
M
U E N C H
E
N
4
R
A
C
K
1
R
A
D
1
7
A
M
1
2
4
.
6
7
5
+
7
.
5
S
C
L
O
C
I
N
A
C
T
C B I T S
T
A
T
U
S
:
W
A
R
N
I
N
G
3 3 1 V
S
W
R
A
B
O
V
E
2
W
Fig. 3.11 Standard operating display
Line Display text Description
1 SU4200
21:04:13
Device type: VHF transmitter
Display: time of day
2 MUENCHEN4 RACK1 RAD17 Location information, optional text. It can be entered
via USB service PC (see chapter
3.3). Only the first
line is displayed.
3 + 4 124.675
AM
+7.5
Frequency in ICAO format. Example shows frequency
value with 25 kHz spacing
AM/ACARS modes
Offset TX, set to +7.5 kHz
5 + 6 LOC
INACT
SC
Local control mode
Radio in inactive state (standby). For example, radio
was switched to inactive via remote control command.
Single channel configuration has been configured via
USB.
7 + 8 CBIT STATUS: WARNING
331 VSWR ABOVE 2 W
CBIT status line. In normal case OK is indicated.
Otherwise, warning or error is indicated (if at least one
notice is present).
If there are more notices, they are displayed in
sequence.
Note: The “W” at the end of a message means that
this is a warning. Generally there are two types of
displayed CBIT messages:
“W” for warning
“E” for error