EasyManua.ls Logo

Rohde & Schwarz SU 4200 - Checking the CBIT State

Rohde & Schwarz SU 4200
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Visual Inspection R&S SU 4200
4.3 6125.0226.12.01
Indication Possible cause of fault Remedy
LED GO
not illuminated
CBIT detected error
(At least one CBIT error or NOGO
warning exists in the radio)
Check CBIT status
Check NOGO configuration via
service PC
Check radio environment (antenna,
DC voltage)
LED VOP
not illuminated
Radio set to "OFF"
(standby operation). Display shows
INACT in standard operating display.
Hardware input *OFF on rear panel
connector X5.7 is connected to
ground.
Radio was switched off remotely via
remote control command or locally
via front panel of the radio.
Activate radio using proper remote
control command (see chapter
6.3.1.5) or switchover to active
mode locally (see chapter
3.4.7.2)
Check hardware Input *OFF on
connector X5.7 if a
contact to ground is applied.
Activate radio using proper remote
control command or switch-over to
active mode locally.
4.1.3 Checking the CBIT State
Displayed warnings
and/or error
messages
For detection of device and system failures, continuous built-in test (CBIT)
functions are implemented in the equipment.
The CBIT starts directly after switching on the transmitter
Warnings and/or error messages produced during ongoing operation
are displayed in the CBIT STATUS menu (see chapter
3.4.7.5)
When malfunctions (warning or error message) are detected, the failure
is signalled to the connected remote control unit.
CBIT always indicates the existing state, which means that as long as a
message is being indicated by CBIT, this problem persists.

Table of Contents

Related product manuals