R&S SU 4200 List of Remote Control Commands
6125.0226.12.01 6.16
6.3.1.4 Session Control (SC)
Code Command/
parameter
Module Type Unit Step
size
Range Default Description
PG Ping
Timeout
TX GET,
SET
s 1 1 to 999 20 Gets and sets
timeout for
ping
mechanism.
SL Current
Session List
TX GET,
TRAP
– – List – For all
connected
clients.
SS Request for
Session
TX GET,
SET,
TRAP
– – Monitor/
Fixed
session
– Gets and sets
type of
session for
client.
6.3.1.5 Main/Standby (MS)
Code Command/
parameter
Module Type Unit Step
size
Range Default Description
AC Inactivate
Radio
TX GET,
SET,
TRAP
– – OFF/AUTO AUTO
GO Skip to GO TX SET – – – – Triggers
transition of
the radio to
GO state.
TY Main/
Standby
Type
TX GET – – 0/1 0 Provides
main (0=A)/
standby (1=B)
configuration
mode that
indicates in
which state
the radio is
after
booting (in
normal case).