List of Remote Control Commands R&S SU 4200
6.15 6125.0226.12.01
Code Command/
parameter
Module Type Unit Step
size
Range Default Description
IP TCP/IP
Address of
One Radio
Module
TX GET IP address
Netmask
Gateway
192.168.52.102
255.255.255.0
192.168.52.1
Provides IP
address,
netmask and
gateway of
one radio
module.
LO Location
Info
TX GET
SET
10 lines each,
max. 20
characters
No text
LT Measure TX
Audio Level
TX GET dBm 1 –30 to +10
dBm settable
via software
– Measures
current audio
level on TX
audio input
(connector
X5).
ND Inventory
Detail
TX GET Provides
detailed
information
such as ID
No., serial
number,
version index.
TI Setting RTC TX GET,
SET
– – YYYY/MM/DD
and
hh:mm:ss
– Gets/Sets
date and time
of all radio
modules.
UO User Output TX 0=OFF,
1=ON
Sets the user
contact of
output port
given in the
first
parameter.
UI User Input TX GET,
TRAP
0=OFF,
1=ON
0=OFF Provides the
input signal of
user contacts.
VE GB2PP
Version
TX GET Text Provides the
ICD version
which applies
for the current
software
release.