R&S SU 4200 List of Remote Control Commands
6125.0226.12.01 6.12
Code Command/
parameter
Module Type Unit Step
size
Range Default Description
TO Carrier
Offset
TX GET,
SET,
TRAP
kHz – –7.5 / –7.3 /
–5 / –2.5 / 0
/ +2.5 / +5
/+7.3 /+7.5
– Gets and sets
TX
frequency
offset.
TR Frequency TX GET,
SET,
TRAP
MHz 8.33
kHz/
25 kHz
112.000 to
155.991
112.000 to
155.975
124.1
MHz
6.3.1.2 Radio Control (RC)
Radio Contro l\Radio Co ntrol "Radio ".doc
Code Command/
parameter
Module Type Unit Step
size
Range Default Description
DP PTT Timeout TX GET,
SET
s 1 3 to 300
(0=disabled)
30 Gets/sets of
timeout for
PTT.
IT Inhibit TX TX GET,
SET
– – 0/1 0 Suppresses/
permits
transmission
MO Measure
Modulation
Depth
TX GET,
TRAP
% 1 0 to 95 – Gets current
value for AM
modulation
depth
according to
input voice
signal.
MV Measure DC
Voltage
TX GET,
TRAP
V 0.1 0 to 32 – DC battery at
X2, internal
DC voltage.
PF Trigger Test
PTT
TX SET – – ON/OFF OFF Transmits w/o
modulation in
CW mode.
PL Power Level TX GET,
SET,
TRAP
W 1 0 to 60 – Transmission
power level.
PP Preset Page
Number
(select page)
TX GET,
SET,
TRAP
– 1 1 to 200 Manual
operation
Provides an
index of
current active
page. Sets
specified
preset page
to active.
PT Trigger Test
Tone
TX SET – – ON/OFF OFF Transmits
with
modulation
AM 90 %, AF