List of Remote Control Commands R&S SU 4200
6.13 6125.0226.12.01
Code Command/
parameter
Module Type Unit Step
size
Range Default Description
PV Preset Page TX GET,
SET
MHz 8.33 kHz
25 kHz
112.000 to
155.991
112.000 to
155.975
124.1 Saves and
loads a preset
page with
frequency,
offset and
spacing.
TO TX Power
(analog value)
TX GET,
TRAP
W 1 0 to 50 Measures
current value
of TX power.
TP Measure
Temperature
TX GET,
TRAP
ºC 1 –20 to +120 Measures
current value
of
temperature:
TX boards,
PSU.
TS TX Power
Level
TX GET,
SET,
TRAP
– – Low/
Normal
Normal
TV VSWR Value TX GET,
TRAP
0.1 1 to 26.5 Measures
current
(analog)
value of
VSWR during
active
transmission.
TW VSWR LED
(digital)
TX GET,
TRAP
– – ON/OFF Indicates
VSWR value.
Corresponds
to carrier
LED.
VV External
VSWR
Voltage
TX GET,
TRAP
V 0.1 0 to 5 Measures
current
voltage value
of external
VSWR input
(X7.8). This is
a permanent
measure-
ment
(not only
during
transmission).

Table of Contents