Maintenance that Should Be Performed Daily
58
Chapter 3 Maintenance Chapter 3 Maintenance
When the screen shown on the left appears, detach the
bottle, and empty it to discard the discharged uid.
CAUTION
Before you detach the drain bottle, be sure to wait for the screen to display
[EMPTY DRAIN BOTTLE].
Failing to follow this procedure may cause discharged uid to ow out of the
tube and spill, soiling your hands or the oor.
WARNING
Never place discharged uid near open ame.
Doing so may cause re.
CAUTION
To store discharged uid temporarily, place it in the included drain bottle
or in a durable, sealed container such as a metal can or polyethylene tank,
and cap tightly.
Any spillage or vapor leakage may cause re, odor, or physical distress.
Do not store discharged liquids in a location where they are exposed to direct sunlight.
When temporarily storing discharged uid in the included drain bottle, do not store in a location that
is exposed to direct sunlight. The discharged uid may harden, making the drain bottle unusable.
Dispose of discharged uid properly, in accordance with the laws in effect in your locale.
Discharged uid is ammable and contains toxic ingredients. Never attempt to incinerate discharged
uid or discard it with ordinary trash. Also, do not dispose of it in sewer systems, rivers, or streams.
Doing so may have an adverse impact on the environment.
Upper limit
Discard before it