EasyManua.ls Logo

Roland LEF-12 - Technical Specifications and Drawings

Roland LEF-12
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Handling Messages and Error Messages
87
Chapter 4 Appendix Chapter 4 Appendix
An Error Message Appears
This section describes the error messages that may appear on the machine's display, and how
to take action to remedy the problem. If the action described here does not correct the problem,
or if an error message not described here appears, contact your authorized Roland DG Corp.
dealer.
[AREA TOO SMALL CONTINUE?]
The Size of the Data is Larger than the Print Area of the Loaded Media
To print immediately, press . The portion extending beyond the print area will not be printed. To
stop printing, stop sending data from the computer and hold down
for one second or longer. Make
the print area wider by replacing the media with a larger piece of media or by changing the position of the
media, then send the data again.
[PRINT AREA TOO SMALL]
The Size of the Test Print is Larger than the Print Area of the Loaded Media
Press any key on the operation panel to go back to the main menu. Make the print area wider by replacing the
media with a larger piece of media or by changing the position of the media, then send the data again.
[CANCELED FOR TABLE HEIGHT]
Detected that the Media is in a Position (Height) of Hitting the Print Head
Remove the media or change its position. Press any key (except the sub power switch) on the operation panel,
and the message disappears. If the setup of the media is completed, the setup is canceled. Redo the setup.
P. 11, "How to Secure the Media"
P. 13, "Set height position of media (automatic)"
P. 15, "Set height position of media (manual)"
P. 17, "Specify the print area directly"
P. 19, "Specifying the Print Area from the Print Center Position"
[TEMPERATURE IS TOO HIGH **°C]
The temperature of the location where the machine is installed has risen above the ambient
temperature at which the machine can operate
Operation cannot be continued. Turn o the sub power. The displayed temperature is the current ambient
temperature of the installation location. Bring the installed location to a temperature at which operation is
possible (20 to 32°C or 68 to 90°F) and allow the machine to come to room temperature, and then turn on
the power.
[SERVICE CALL xxxx]
An unrecoverable error occurred, or part replacement that must be performed by a service
technician is required
Note the number displayed on the display screen, and then switch o the sub power. After you switch o the
power, inform your authorized Roland DG Corp. dealer of the number that appeared on the display screen.
[TEMPERATURE IS TOO LOW **°C]
The temperature of the location where the machine is installed has fallen below the ambient
temperature at which the machine can operate
Operation cannot be continued. Turn o the sub power. The displayed temperature is the current ambient

Table of Contents