Handling Messages and Error Messages
86
Chapter 4 Appendix Chapter 4 Appendix
[SETUP MEDIA]
Reload the media and press . This message appears when an attempt to perform a printing test was
made while no media was loaded.
[INSTALL DRAIN BOTTLE]
Check whether the drain bottle is installed. Install the drain bottle, then press .
[CHECK DRAIN BOTTLE]
This message appears when a certain amount of discharged uid collects in the drain bottle. To clear the
message, press
. If this screen appears, go to the [DRAIN BOTTLE] menu and discard the discharged
uid in the bottle.
P. 57, "Disposing of Discharged Ink"
[TIME FOR MAINTENANCE]
It is time to perform manual cleaning. After verifying, press .
P. 62, "Manual Cleaning"
[TIME FOR WIPER REPLACE]
It is time to replace the wipers. After verifying, press .
P. 71, "Replacing the Wiper"
[TIME FOR FILTER REPLACE]
It is time to replace the lters. After verifying, press .
P. 74, "Replacing the Filter"
[READJUST TABLE HEIGHT]
The Height of the Media was Automatically Re-set, and Printing was Finished.
Although the media came into contact with the media gap sensor during printing, the height of the media
was automatically re-set, and printing was nished because "CLEARANCE MODE" is set to "RE-ADJ".
P. 15, "Set height position of media (manual)"
P. 17, "Specify the print area directly"
P. 19, "Specifying the Print Area from the Print Center Position"
P. 40, "Even when the media comes into contact with the media gap sensor during printing, automatic adjustment
is performed to continue printing."