Handling Messages and Error Messages
Chapter 4 Appendix
88
Chapter 4 Appendix
temperature of the installation location. Bring the installed location to a temperature at which operation is
possible (20 to 32°C or 68 to 90°F) and allow the machine to come to room temperature, and then turn on
the power.
[DATA ERROR CANCELING...]
Output was stopped because a problem was found in the data received
Operation cannot be continued. Check whether or not there is an error in the data. Check for a problem with
the connector cable or the computer, and redo the operation from the starting with loading the media.
[WRONG CARTRIDGE]
A cartridge that cannot be used was installed
Remove the ink cartridge to clear the error. Use an ink cartridge of the specied type.
[WRONG HEAD IS INSTALLED]
A print head that cannot be used is installed
Turn o the sub power. After turning the power o, contact the your authorized Roland DG Corp. dealer.
[AVOIDING DRY-UP TURN POWER OFF]
The print heads were forced to standby position to prevent them from drying out
Operation cannot be continued. Switch the sub power o, and then back on. Opening the front cover while
printing is in progress causes an emergency stop. Never allow the print heads to remain in this state.
[MOTOR ERROR TURN POWER OFF]
A motor error occurred
Operation cannot be continued. Turn o the sub power. Next, eliminate the cause of the error, then immediately
switch on the sub power. If the machine is allowed to stand with the error uncorrected, the print heads may
dry out and become damaged. This error may be caused by the media being set incorrectly.
[CANCELED FOR MOTOR PROTECTION]
Continuous operation made the pump motor become hot so operation was paused
Press any key to clear the error. Allow the machine to stand for approximately 40 minutes before resuming
operation.