Read this chapter whenever you face a problem. (FAQ)
81
Chapter 4 AppendixChapter 4 Appendix
Is the Link LED lit?
If the Link LED for the Ethernet connector is not lit, the
network connection has not been made correctly. Check
whether or not the network routing is appropriate. Try
connecting the computer and the machine to the same
hub or connecting them directly using a crossover cable.
If this makes it possible to perform output, it means the
problem is in the network itself.
Are the network settings correct?
If output is not possible even though the link LED is on, make sure the IP address and other settings are cor-
rect. The settings on both the machine and the computer must be appropriate. Redo the settings, checking
to ensure that the IP address does not conict with the IP address for another device on the network, that the
port setting for the software RIP species the IP address set on the machine, that the settings have no typing
errors, and for other such problems.
P. 49, "Viewing Information about the System of This Machine"
“First Step Guide”
Did the software RIP end abnormally?
Make sure the software RIP is running correctly, then switch the sub power switch o and back on.
“Roland VersaWorks Quick Start Guide”
Is the temperature of the room too low?
Use the machine in an environment where the temperature is 20 to 32°C (68 to 90°F).
The Flat Table Does Not Move
Is something stuck in the X-axis, Y-axis, or Z-axis movable axes?
Check whether or not something is catching or stuck and interfering with operation.
Are any covers open?
Close the front cover and panel cover while starting up or printing. If any cover is open while starting up or
printing, the at table cannot be moved for your safety.
The Media Gap Sensor Does Not Sense Media
Is something covering the media gap sensor or has it attracted dust?
Check whether or not something is interfering with the media gap sensor's ability to sense.