Power supply
Mains Voltage Single Phase 230 VAC (Outside the US & CANADA)
115 VAC 0.5A (US & CANADA)
Mains Frequency 50/60HZ
Maximum Power Consumption 40W
Main Fuse
Main Fuse (12V) 125/250V 100mA T
Main Fuse (Switching P.S)) 125/250V 2A T
Connection Box peripheral
Digital inputs
8 Digital Inputs Dry Contact 5V/2mAmp
Relays outputs
N.C/N.O. (OMI) Blue Small Low Power Relay 5Amps 250VAC
Alarm output
N.O and N.C (Double) (OMI) Pilot Duty 5Amps 250VAC
Housing
Metal Box Dimensions (LxWxH) 262x262x80mm
Ambient climate
Operating Temperature Range 0 to +50 C° (32 to 125 F°)
Operating Humidity Range 0% to 95%
Storage Temperature Range -10 to +70 C° (14 to 158 F°)