Poultry House Control
50
8. Non Brood Area Temperature: while in brood, the non-brood heaters operate to this
temperature setting.
9. Radiant Low Differential From Heat: this sets the temperature below the heat
temperature at which radiant brooders light.
10. Radiant High Differential From Low: this sets the temperature below the
corresponding low level radiant heater at which the high level radiant heater lights.
11. Radiant Ignition Time: this is the length of time the ignitor is active.
Minimum-Maximum Levels
Minimum – Maximum Level
By Day By Time Soft Minimum by Day
Day Min Max From
Time
Min Max Day Min
Cold
Min
Warm
Max
1 5 21 8:00 5 21 1 5 7 25
20:00 3 21
Help | Set Parameters
Low Temperature: 50
Notes: Notes:
High Temperature: 80
The entire ventilation range provided in the ventilation table is too large at any
particular bird age. Select the appropriate range of ventilation in the Min/Max level table.
You can optionally select this by bird age, by time of day, or soft minimum.