Poultry House Control
52
Foggers
Foggers
Day Start Time End Time Target
Diff
To % RH On Sec Off Sec
21 10:00 18:00 15.0 75% 30 270
Help | Set Parameters
Temperature Band Humidity Band
The fogger table allows several settings. In some cases you may interchange the use of
the Cooling table and the Fogger table, since they both control evaporative cooling. The
Cooling table operates at a differential from the tunnel entry temperature, while the fogger
table operates at a differential from target temperature settings.
Stir Fans
The stir fan menu selects from 5 different special programs for each stir fan. Check the
programs that apply to each stir fan using the +/- key. The programs are for designed for the
following:
A. Minimum Ventilation: this program helps mix minimum ventilation air for buildings that
have side vents which do not properly mix the air.
B. End to End Temperature Variation: this program corrects temperature variations
lengthwise in the building.
C. Heat Recovery: this program brings warm ceiling air down to the birds.
D. General Purpose
: same as E.
E. General Purpose
: programs D and E are connected to ventilation levels for general
purpose use.