EasyManua.ls Logo

Rotem Platinum PLUS - Page 53

Rotem Platinum PLUS
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Platinum Plus
53
Stir Fan Settings
Fan Prog A Prog B Prog C Prog D Prog E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Help | Set Parameters
Param
1
At End or
Start
END
Sensor Diff
4.0ºF
Target Diff On Time On Time
Param
2
Delay
0
Sensor 1
One
On Time Off Time Off Time
Param
3
Run Time
20
Sensor 2
Five
Off Time From Level From Level
Param
4
From Level
0
On Time
100 sec
From Level To Level To Level
Param
5
To Level
30
Off Time
200 sec
To Level From Time From Time
Param
6
From Time
00:00
From Level
1
From Time To Time To Time
Param
7
To Time
00:00
To Level
10
To Time
Param
8
From Time
00:00
Param
9
To Time
00:00

Table of Contents

Other manuals for Rotem Platinum PLUS