Poultry House Control
54
Lights
The LIGHT Menu provides up to 50 on and off times. Note that all times are in 24
hour military format. The entry for day 1 ensures continuous light. This program assumes no
light dimmer installed. The Platinum Plus can optionally control intensity settings with a slave
light dimmer, including sunrise and sunset effects.
Light
Day Start End Intensity
1 00:00 00:00 100
4 00:00 14:00 100
4 16:00 22:00 100
8 00:00 12:00 100
8 16:00 22:00 100
Feed
The FEED menu can be programmed to correspond to the light table, or simply enter
the first line only to allow the control hopper to run the feed system.
Feed
Day Start End
1 00:00 00:00
Extra Systems
The EXTRA SYSTEMS are a set of 4 controls you can use for various purposes. For
example, use Extra System 1 for the Fail Safe system by programming it to be always on as
shown. Then, in the event of power failure or some other types of controller failure, this relay
will activate the fail safe backup.
Extra Systems
Parameter System 1 System 2 System 3 System 4
Start Time 00:00
End Time 00:00
From Temp 0
To Temp 122.0
From Humidity 0
To Humidity 100
On Seconds 1
Off Seconds 0
Static Pressure
The STATIC PRESSURE settings control air pressure in side (minimum) ventilation
and in tunnel ventilation. To view the optional parameters, press the Help key and then choose