EasyManua.ls Logo

RuggedCom RMC30 - SNMP Trap Summary

Default Icon
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix B. SNMP Trap Summary
ROS® v3.11User Guide 119 RMC30
Appendix B. SNMP Trap Summary
The switch generates the standard traps summarized in the following table.
from IF-MIB: linkDown, linkUp
from SNMPv2-MIB: authenticationFailure coldStart
from BRIDGE-MIB: newRoot, topologyChage
from RMON-MIB: risingAlarm, fallingAlarm
from LLDP-MIB: lldpRemoteTablesChange
The switch also generates the proprietary traps which are summarized in this document with
their severity levels. These traps are described in the RC-TRAPS-MIB.
genericTrap,
powerSupplyTrap,
swUpgradeTrap,
cfgChangeTrap
weakPasswordTrap
Generic Traps carry information about event in severity and description objects. They are
sent at the time that an alarm is generated for the device. The following are examples of
RuggedCom Generic Traps, along with the severity of each one in brackets:
heap error (alert)
NTP server failure (notification)
real time clock failure (error)
failed password (warning)
MAC address not learned by switch fabric (warning)
BootP client: TFTP transfer failure (error)
received looped back BPDU (error)
received two consecutive confusing BPDUs on port, forcing down (error)
GVRP failed to learn – too many VLANs (warning)
The information about generic traps can be retrieved using CLI command alarms.
The switch generates the following traps on specific events:
from RUGGEDCOM-STP-MIB: rcRstpNewTopology generated after topology becomes
stable after a topology change occurs on a switch port.
from RUGGEDCOM-POE-MIB: rcPoeOverheat and rcPoeOverload – generated by Power
over Ethernet (PoE) overheat and overload conditions, respectively. These traps are only
generated by RS900GP devices.

Table of Contents