2. Serial Protocols
ROS® v3.11User Guide 69 RMC30
The device address table in which addresses will be found for unicast messages.
Link Stats
Synopsis: { Disabled, Enabled }
Default: Enabled
Enables link statistics collection for this protocol.
WIN DSCP
Synopsis: 0 to 63
Default: 0
To set the DS byte in the IP header. DS byte setting is supported in the egress direction
only.
TIN DSCP
Synopsis: 0 to 63
Default: 0
To set the DS byte in the IP header. DS byte setting is supported in the egress direction
only.
2.3.8. MicroLok
Figure 2.22. MicroLok Form
Transport
Synopsis: { TCP, UDP }
Default: UDP
The network transport used to transport protocol data over an IP network.
IP Port
Synopsis: 1024 to 65535
Default: 60000