1. Administration
ROS® v3.11User Guide 30 RMC30
Default: noPriv
An indication of whether messages sent on behalf of this user to/from SNMP engine can
be protected from disclosure, and if so, the type of privacy protocol which is used.
Auth Key
Synopsis: 31 character ASCII string
Default:
The secret authentication key (password) that must be shared with SNMP client. if the key
is not an emtpy string, it must be at least 6 characters long.
Confirm Auth Key
Synopsis: 31 character ASCII string
Default:
The secret authentication key (password) that must be shared with SNMP client. if the key
is not an emtpy string, it must be at least 6 characters long.
Priv Key
Synopsis: 31 character ASCII string
Default:
The secret encription key (password) that must be shared with SNMP client. if the ke is
not an emtpy string, it must be at least 6 characters long.
Priv Key
Synopsis: 31 character ASCII string
Default:
The secret encription key (password) that must be shared with SNMP client. if the ke is
not an emtpy string, it must be at least 6 characters long.
1.12.2. SNMP Security to Group Maps
Entries in this table map configuration of security model and security name (user) into a group
name, which is used to define an access control policy. Up to 32 entries can be configured.
Figure 1.17. SNMP Security to Group Maps Table