Table 11 – Alarm Relay Wires
Figure 10 – Alarm Relay
3.8 System Configuration
When the physical and electrical installation of the system is complete, the R5 SOLID
needs to be configured. The installer is required to set the parameters listed below. For
detailed information about the configuration parameters and how to set them, refer to
section 4.2.1 and 4.4.
MMSI number (Maritime Mobile Service Identity)
IMO vessel number (should be set to zero for Inland vessels)
Call Sign
Ship Name
Ship Type (Only when operating in Class A mode)
Height Over Keel
Ship dimensions and antenna positions. Refer to section 4.4.4 Main Menu
Config Ship Dimensions for more information.
If the R5 SOLID is operating in Inland mode, the following parameters also need to be
configured:
ENI, Unique European Ship Number
ERI Ship Type (ERI code and standard AIS ship type will be set automatically by
the R5 SOLID when selecting an ERI Ship Type from list in Ship Static view.
Quality setting for SOG, COG and HDG. Should be set to low if no type approved
sensor (e.g. a gyro or speed log) is connected to R5 SOLID.