44
17.11. Solar Application scheme K
Charging A Buffet with a solar panel. „Container-in-container” type buffer. The regulator supports CH
system.
Fig. 17.11 Application scheme K
*Pumps marked in the scheme as P are not controlled by regulator.
Installation recommendations
1. Two additional CT6 sensors are required for the application schema.
2. Connect the circulation pump to the H output via the relay. It is necessary to use a relay type
6VDC RM85-2021-35-1006.
Setting recommendations
3. Do not set HP2 value higher or equal to dTAB, because this will prevent loading stop when dTAB
value is reached.
Sensor T3 [+]
Sensor T3 [-]
Output H [+]
Output H [-]
Mains 230~
Supply L
Supply N
Pump P1 [N]
Pump P1 [L]
Pump P2 [L]
Pump P2 [N]
Sensor T1 [+]
Sensor T1 [-]
Sensor T2 [+]
Sensor T2 [-]
Sensor T4 [+]
Sensor T4 [-]

Table of Contents