4.Troubleshooting
ScanAreaAdjustment
•Diagnostics>Adjustment>ScanAreaAdjustment>AutomaticAdjustment
PurposeTocorrectimagepositionandmagnicationofscannedimagesautomatically.
OperationProcedure
1)LocatetheScannerA/SChartatthescanglass.Notethat“LeadEdge”arrowsneedtohead
totheleftsideofscanglassandtobeplacedfacedown.AlsonotethattheScannerA/S
Chartscomeintwosizes,A4andLetter.Chooseonesizetomeetyourprimarysizeofuse.
2)Press“OK”button.Automaticscanningwilloccur,andthesystemwillautomatically
calculatethepropervaluebasedonscanningresultofthechart.
3)Thenewvaluesettothetable.
Verication
1)ScantheScannerA/SChartandsendittoaPC.Scanningmustbeoccurfromthescanglass.
2)Tochecktheimageposition,comparethepositionofscalemarks(a,b)ofthechartto
thecopy.
3)Tocheckthemagnication,comparethelengthofline“c”ofthecharttothecopy.
Specicationa,b:10,±1.5mm
c:190,±1.5mm
ReferenceA4ScannerA/SChart