● Code :
A3-3211
A3-3212
● Error message :
● Symptom / Cause :
Inner temperature sensor is short or open.
The output of the Inner temperature sensor is more th
● Troubleshooting method :
1. Turn the machine off and on.
2. Check the output of the inner temperature sensor. (
3. Check the engine board.
Inner temperature sensor
● Replacement part
- JC32-00005A : SENSOR-HUMIDITY
- JC92-02302A : PBA-ENGINE (SCX-8030ND)
- JC92-02221A : PBA-ENGINE (SCX-8040ND)
Service Manual
SCX-8030/8040 series
7-
ure #A3-3211: Turn off then on.
ure #A3-3212: Turn off then on.
efer to 3.7.16 in the chapter 3)
SAMSUNG ELECTRONICS
Version 0.05