PY Manual Copyright © 2006 SANYO DENKI AMERICA, Inc.
85
Feed Forward, Low Pass Filter FLPF
Remote Operator Mode:
0
Page:
4
Default Value:
1000 Hz
Function:
Tune
Setting Range:
1 to 1000 Hz
Description:
The cut-off frequency of the low-pass filter is set for the feed-forward command of the position loop.
Velocity Command, Low Pass Filter VLPF
Remote Operator Mode:
0
Page:
5
Default Value:
1000 Hz
Function:
Tune
Setting Range:
1 to 1000 Hz
Description:
The cut-off frequency of the velocity command low-pass filter.
Current Command, Low Pass Filter ILPF
Remote Operator Mode:
0
Page:
6
Default Value:
450 Hz
Function:
Tune
Setting Range:
1 to 1000 Hz
Description:
The cut-off frequency of the current command low-pass filter.