Current Limit, Sequence SILM
Remote Operator Mode:
1
Page:
12
Default Value:
120 %
Function:
Current Limit
Setting Range:
30 to (IP/IR) x 100
Description:
• This current limit applies under the following conditions: holding brake sequence, over-travel, and while
jogging.
•
Even if this parameter is set to a value larger than the peak current, the actual current will be limited to the peak
current.
•
Changes to this parameter do not take affect until the control power is cycled “OFF” and back “ON”.
•
The setting is a percentage of rated current (IR).
Holding Brake Excitation Timing THB
Remote Operator Mode:
1
Page:
13
Default Value:
300 ms
Function:
Setting Range:
0 to 1000 ms
Description:
• Sets the holding brake excitation timing.
•
Select “0” when this function is not used.
Velocity Command, Scale Adjustment VCMS
Remote Operator Mode:
1
Page:
14
Default Value:
500 min
-1
/V
Function:
Setting Range:
0 to 3000 min
-1
/V
Description:
• Sets a velocity command scale corresponding to 1V of the command voltage.