Current Limit, Sequence SILM
Remote Operator Mode:
1
Page:
12
Default Value:
120 %
Function:
Current Limit
Setting Range:
30 to (IP/IR) x 100
Description:
This current limit applies under the following conditions: holding brake sequence, over-travel, and while
jogging.
Even if this parameter is set to a value larger than the peak current, the actual current will be limited to the peak
current.
Changes to this parameter do not take affect until the control power is cycled “OFF” and back “ON”.
The setting is a percentage of rated current (IR).
Holding Brake Excitation Timing THB
Remote Operator Mode:
1
Page:
13
Default Value:
300 ms
Function:
Setting Range:
0 to 1000 ms
Description:
Sets the holding brake excitation timing.
Select “0” when this function is not used.
Velocity Command, Scale Adjustment VCMS
Remote Operator Mode:
1
Page:
14
Default Value:
500 min
-1
/V
Function:
Setting Range:
0 to 3000 min
-1
/V
Description:
Sets a velocity command scale corresponding to 1V of the command voltage.