Operating Instructions Combics Indicators  147
  Menu Structure 
  setup / WP-1 / intern.  Param.2
  2.WT.UNIT 2nd weight unit (depends on the weighing platform type)  3.1
                 
1)
not for use in legal metrology 
    GRAMS   Grams /g    3.1.2*
    KILOGR.  Kilograms /kg    3.1.3
    CARATS   Carats/ct
1) 
  3.1.4
    POUNDS   Pounds/lb
1) 
  3.1.5
    OUNCES  Ounces/oz
1) 
  3.1.6
    TROY.OZ.  Troy ounces/oz
1) 
  3.1.7
    HK TAEL  Hong Kong taels/tlh
1) 
  3.1.8
    SNG.TAEL  Singapore taels/tls
1)
    3.1.9
    TWN.TAEL  Taiwan taels/tlt
1)
    3.1.10
    GRAINS  Grains/GN
1)
    3.1.11
    PENNY.WT.  Pennyweights/dwt
1)
    3.1.12
    MILLIGR.  Milligrams/mg
1)
    3.1.13
    PT.P.LB  Parts per pound/lb
1)
    3.1.14
    CHN.TAEL  Chinese taels/tlc
1)
    3.1.15
    MOMMES  Mommes/mom
1)
    3.1.16
    AUSTR.CT  Austrian carats/K
1)
    3.1.17
    TOLA   Tola/tol
1)
    3.1.18
    BAHT  Baht/bat
1)
    3.1.19
    MESGHAL  Mesghal/MS
1)
    3.1.20
    TONS  Tons/t      3.1.21
  2.DIS.DIG. Display accuracy  3.2
    ALL   Show all decimal places    3.2.1*
    -1.WT.CHA  Reduced by 1 digit    3.2.2
    RES.*10  10-fold increased resolution  3.2.14
    +DIV. 2  Increase resolution by 2 scale intervals  3.2.15
    +DIV. 1  Increase resolution by 1 scale interval  3.2.16
  setup / WP-1 / intern.  Reset  Factory settings
  WT.PARA Restore factory default settings  9.1
    NO  No      9.1.1*
    YES  Yes      9.1.2
  setup / WP-1 / intern.  ADC-CON  Analog/Digital converter configuration (ADC)
1)
    standrd   Standard
    VERIF.  Verifi able
  setup / WP-1 / OFF
2)
  setup / WP-1 / com1
  setup / WP-1 / unicom 
3)
  rs-232 RS-232* menu parameters depending on the connected complete scale
  rs-485 RS-485 menu parameters depending on the connected complete scale
  setup / WP-1 / com-wp
2)
 
  rs-232 RS-232* menu parameters depending on the connected complete scale
  rs-485 RS-485 menu parameters depending on the connected complete scale
  setup /com-1  off
  setup /com-1  WP 2  Weighing platform 2
2)
  RS-232*   
    SBI standard 
    SBI trade version (for legal metrology) 
    xBPI-232 
      Menus 1.1 to 1.8 same as for WP1 
      Calibration/Adjustment    1.9
      Ext. calibration/adjustment; default weight*  1.9.1
      External calibration/adjustment; 
      weight can be selected (1.18.1)  1.9.3
      Internal cal./adj.     1.9.4
      No function when you press the J key  1.9.10
      Menus 1.10 to 9.1 same as for WP1 
      ADC-232 
      Menus 1.1 to 9.1 same as for WP1 
1) 
Only in Service mode
2) 
Combics 2 only
3) 