Operators Handbook DCU3 – System
10., Main Function „Documentation“
BAEDCU3 - Rev. 4.6 - 0504 10 - 3
10.3 Recorder Configuration
Optionally the DCU system can have a recorder output board. This board offers 6 analog outputs
0 ... 10 V for the connection of a 6-channel dot printer.
The 6 recorder outputs must be assigned to the process values in the DCU - system via the main func-
tion „Documentation“. In addition to the channel assignment you can individually select the measure-
ment range for the process values.
10.3.1 Operating Display
Tag Entry Displayed value or function, required input
Channel 1 ... 6 Display of recorder channel
Process Value Tag PV Input of process value (Tag of PV)
Minimum [PV] Input of lower limit of parameter display in physical units of the
process value [PV]
Maximum [PV] Input of lower limit of parameter display in physical units of the
process value[PV]
10.3.2 Special Notes
For the connection of a 6-channel dot recorder the option „Recorder output board DCU1 -
system“ or „Extension 12 analog outputs DCU2/3 - system“ must be installed.
For the plug assignment of the recorder connection please refer to the Technical Manual.