SATEL INTEGRA Plus 17
[1] full arming + bypasses (allows the users to stay in the protected area) – the zones for
which the BYPASSED IF NO EXIT option is enabled by the installer will be bypassed,
[2] arming without interior (allows the users to stay in the protected area):
interior zones (3. INTERIOR DELAYED zone type) will be disarmed,
violating the exterior zone (8. EXTERIOR zone type) will trigger a silent alarm,
violating another alarm zone will trigger a loud alarm.
[3] arming without interior and without entry delay (allows the users to stay in the
protected area – to be used when nobody else is to enter the protected area) – this
arming mode is similar to the previous one, but the delayed zones operate as the
instant ones (no entry delay).
Cancel 1st code – if the partition is armed/disarmed by means of two codes and the first
code has already been entered, the user can still cancel the consent to arming/disarming.
Change own code – allows the user to change his/her own code.
Change telephone code – allows the user to change his/her own telephone code.
Change prefix – available to the administrator, if the use of prefixes in the system has been
made available by the installer (the prefix length has been defined). It enables to program
the prefixes and the time to remind about the need to change the prefix. Each code will
have to be preceded by a prefix:
normal – for everyday use. By default, it consists of a suitable number of digits 0 (e.g. if
the determined prefix length is 4, the default prefix is 0000),
DURESS – for use, when the user has been forced to enter the code. Using the code will
trigger a silent alarm. By default, it consists of a suitable number of digits 4 (e.g. if the
determined prefix length is 3, the default prefix is 444).
Users – the following functions are available in the submenu:
New user – allows to create a new user (see: “Adding new user” p. 26).
Edit user – allows to edit the existing users (see: “Edit user” p. 27).
Remove user – allows to remove the existing users (see: “Removing a user p. 27).
The administrator defines whether the installer is to have access to the U
SERS
submenu (SERV. CAN EDIT option in the CHANGE OPTIONS submenu).
Masters – the submenu provides the following functions available to the installer:
New master – allows to create a new administrator.
Edit master – allows to edit the existing administrators.
Remove master – allows to remove the existing administrators.
Zone bypasses – the following functions are available in the submenu:
Inhibit – allows to temporarily bypass the zones (see: “Zone inhibiting” p. 29).
Isolate – allows to permanently bypass the zones (see: “Zone isolating” p. 30).
If the GRADE 3 option has been enabled by the installer, the ISOLATE function is only
available to the installer.
Set time – allows to program the control panel clock. The data are entered in the following
format:
time – hour:minute:second,
date – day:month:year.
System state – allows to view the troubles and, if the GRADE 3 global option has been
enabled by the installer, also the alarms and bypassed zones, as well as to check the
partition status.