18 User Manual SATEL
Events – the submenu contains functions which allow to view the events saved to the control
panel memory (see: “Viewing the event log” p. 31).
Reset zones – running the function will result in a temporary deactivation of the
43. RESETABLE POWER SUPPLY type outputs, thus making it possible to reset the alarm
memory for detectors supplied from those outputs (e.g. fire detectors).
Clear latched outputs – allows to turn off some of the control panel outputs for which the
LATCH option is enabled, as well as the 9. DAY ALARM, 12. SILENT ALARM
and 116. INTERNAL SIREN type outputs.
Fin.f.door open – restores the normal operating mode in all modules executing the access
control functions (in case of fire, the doors controlled by these modules may be
automatically unlocked).
Change options – the following functions are available in the submenu:
Keypad chime – allows to turn on/off the CHIME in the keypad. The CHIME is five short
sounds by means of which the keypad will inform you e.g. that a door / window is open,
when the system is disarmed. The installer defines which zones of the alarm system
can trigger the CHIME.
Outputs chime – allows to block the chime signal from selected partitions on the
11. CHIME type output.
Timers – allows to program parameters of the timers controlling the 120. THERMOSTAT type
outputs, and other timers, the editing of which is permitted by the installer.
Temperatures – allows to edit the temperature thresholds and hysteresis for
120. THERMOSTAT type outputs.
Partition timers – allows to program the partition timers (see: “Programming the partition
timer” p. 32).
No expanders tamper alarms – allows to temporarily disable the expansion module
tamper supervision. In case of any problems with the expansion modules, report the fact
to the installer.
Permanent service access – the option is available to the master user (administrator). If
enabled, the installer has permanent access to the alarm system, which, among other
things, enables the control panel to be programmed by using LCD keypad or DLOADX
program.
Enabling PERMANENT SERVICE ACCESS option will clear the installer access time
programmed with the SERVICE ACCESS function. On the other hand, programming the
installer access time will disable the PERMANENT SERVICE ACCESS option.
Service can edit – the option is available to the master user (administrator). If it is
enabled, the installer can add, edit and delete users in the administrator's object.
Service arm/disarm/clear/bypass – the option is available to the master user
(administrator). If it is enabled, the installer can arm/disarm the system, clear alarms
and bypass zones in the administrator object.
Permanent DLOADX access – the option is available to the master user (administrator).
If it is enabled, the control panel can be programmed by means of the DLOADX
program, irrespective of whether or not the installer has access to the alarm system.
DLOADX IP – enables programming the address of the computer, on which the DLOADX
program is installed. The address must be set if the control panel is to initiate
communication with the DLOADX program through Ethernet, using the TCP/IP
protocols (see: description of the ETHM-1 – DLOADX function, available in the
D
OWNLOADING submenu). It can be entered as a name or IP address.
GUARDX IP – enables programming the address of the computer, on which the GUARDX
program is installed. The address must be set if the control panel is to initiate