SECTION 4
:
FREE MODE
SATO HT200e Page 4-23
DISPLAY ON THE SCREEN FOR PRICE FIELD
Field No. Position of digit
It will go to the entry for character pitch.
Note: Use [FMT] to return to the entry of the format number to be registered.
Press [ENTR] to determine the data selected, so that the entry for fixed data can be reached.
01 01 : FLD TYPE
1 2 : PRICE ▽
0 000000000000000
01 02 : DATA TYPE
2 0 : STANDARD 1 : POP
2
0 00000000000000
01 03 : FONT TYPE
30:X1 1:X2 2:X3 ▽
20
0 0000000000000
01 04 : V-POSITION
4
202
0 000000000000
01 07 : H-POSITION
5
202025
0 000000000
01 10 : ROTATION
60:0° 1:90° ▽
202025032
0 000000
Enter “2” for the field type.
For the data type:
1) Enter “0” in case of Standard.
2) Enter “1” in case of POP.
Value in one digit can be entered for the character type:
1) For Standard, select the value from “0”, “1”, “2”, and
“5”.
2) For POP, select from “0”, “1”, and “2”.
Value in 3 digits can be entered for the vertical position:
Select the values from “001” to “784”.
Note: “000” is a field where only entry is required, so
that no print is made.
Value in 3 digits can be entered for the horizontal
position: Select the values from “001”to “384”.
Value in one digit can be entered for the rotation:
Select the value from “0”, “1”, “2”, and “3”.