10.13 ESC+2D50 DataMatrix (ECC200)
ESC+2D50
HEX Code
When Power is Switched Off
The set parameter is not maintained
The set parameter becomes invalid
Valid Range between Items
The set parameter becomes invalid
[Function]
Specifying DataMatrix Code (ECC200).
[Format] (Setup part)
<2D50>,aa,bb,ccc,ddd
●Parameter
a [Horizontal cell size] = Valid Range : 01 to 16 dots
a [Vertical line width] = Valid range : 01 to 16 dots
c [Number of cell in one line] = Valid Range : 010 to 144
000 : (Auto-setting)
d [Number of cell lines] = Valid Range : 008 to 144
000 : (Auto-setting)
[Format] (Data part)
<DN>mmmm,n to n
●Parameter
m
[Number of data] = Valid Range : 1 to 3116
n
[Print data] = Data
*When print 7EH, specify ”7EH, 7EH”
*If Parameter other than above is specified or print data don’t match, print is not secured.
[Coding Example]
Horizontal cell size: 3 dots, Vertical cell size: 3 dots
<A>
<V>100<H>200<2D50>,03,03,000,000
<DN>0010
0123456789
<Z>
[Supplementary Explanation]
1. If Parameter other than above is specified or print data don’t match, print is not executed
2. When specifying print format, secure more than 2mm blank space in for sides of the DataMatrix for read margin for the scanner.
3. When print data is 7EH, specify ”7EH, 7EH”Number of data will be “0002”.
4.When Auto setup (000) is applied for [Number of cell in one row] and [Number of cell lines] , square DataMatrix is printed