240
13.7 Memory Card
Printer
CL408e/412e
M-8400RVe
CL608e/612e
M-5900RVe
M-10e
M-8485Se/90Se/60Se/59Se M-84Pro-2/3/6 LC408e/412e
13.7 ESC+/N Field Register
ESC+/N
HEX Code
ESC
/N
Parameter
<1B>16
<2F>16<4E>16
,aa,bb
Default Value
NIL
Valid Range &
Terms of
Command
When Power is Switched Off
The set parameter is not maintained
Valid Range within Items
The set parameter is valid until the next specification is made.
Valid Range between Items
The set parameter is valid until the next specification is made.
[Function]
To register item inside of the field at the Format Register Specification <YS>
[Format]
</N>,aa,bb
● Parameter
a {Field No.} = valid range : 1~99
b {Print Digit Number} = valid range : 1~99
[Coding Example]
<A>
<CC>1
<YS>,01
</N>,1,3
<%>0<V>100<H>200<P>2<L>0101<XM>ABC
</N>,2,5
<%>0<V>200<H>200<P>2<L>0101<OA>12345
</N>,3,8
<%>0<V>300<H>40<B>40208049123456
<Z>
[SupplementaryExplanation]
1.Specify the field No. with the order start from the small value.
2.Print Vertical Position Specificatin<V> and Print Horizontal Position Specification <H> shall be specified at every field. It will become default
value if none of the specification is made.
3.Regarding the digit number specification while printing foreign characters
When specify foreign character code “H”, a foreign character needs 4 digits, therefore 3 foreign characters equals to 12 digits.
When foreign character code “B” is specified, a foreign character needs 2 digits, therefore 3 foreign characters equals to 6 digits.
4.Specify the register digit numbers of fixed field out of value 00.
5.Use it with Format Register Specification <YS> as a pair.
6.Due to the limitation of memory quantity, it may not be able to register 99 items.
7.LC408e/412e does not support optional memory card. Please specify {Flash ROM} with Card Slot Specification <CC>.
[Change Print Specification Command]
Font
<XU>
<XS>
<XM>
<XB>
<XL>
<OA>
<OB>
<RD>
<$=>
<K1>
*1
<K2>
*1
<K8>
*1
<K9>
*1
<k1>
*1
<k2>
*1
<k8>
*1
<k9>
*1
Barcode
<B>
<BC>
<BG>
<BI>
<BP>
<D>
<D><d>
<BD>
<BT>
<BW>
*1 Requires optional Kanji ROM. (Not supported for LC408e/412e.)