[Function]
To specify re-call content which is registered in memory card by Form Overlay Register Specification <&S>.
[Format]
<&R>,aa
● Parameter
a {Register Number} = valid range : 1~99
[Coding Example]
<A>
<CC>1
<&R>,1
<Z>
[Supplementary Explanation]
1.Before the Form Overlay Re-Call Specification <&R>, slot number from Card Slot Specification <CC> shall be specified.
2.Form Overlay Re-Call Specification <&R> can perform printing with the combination of different register number.
3.When register number is not specified, the function of Form Overlay Re-Call Specification <&R> becomes invalid.
4.It will become read / write error if non-registered number is specified.
5.When non-specified window is registered, Print Vertical Position Specification <V> and Print Horizontal Position Specification <H>
will be ignored and re-call the drawing area from the beginning (V1, H1).
6.When Window is specified and registered, it is valid to move by specifying Print Vertical Position Specification <V> and Print Horizontal
Position Specification <H>. However, if it exceeds print area, the exceeded area will not be printed out.
7.Form Overlay Re-Call Specification <&R> cannot be used without the memory card.
8.LC408e/412e does not support optional memory card. Please specify {Flash ROM} with Card Slot Specification <CC>.
Form Overlay Re-Call