4
OPERATIONAL INSTRUCTIONS
V23C_09.13
SC4000 Pos 5
S4 - PUSH-BUTTON - FORWARD/UP
S5 - PUSH-BUTTON-REWARD/ DOWN
S6 - EMERGENCY STOP
X6 - PLUG
5.2. OPERATION INSTRUCTIONS
You can easily operate the platform with
the pendant control E3. The pendant con-
trol is connected to a plug X6 with a ca ble.
You can use the pendant control for two
different purposes:
a)
for lifting the platform, when it is con-
nected to a socket X5 on the lifting
mechanism or
Drawing 5.1. Platform electric box OP2.
Q1
- MAIN SWITCH
X1 - SUPPLY SOCKET
X3 - SOCKET
Drawing 5.2.
Chassis electric box OP1.
Drawing 5.3. Pendant control E3
(horizontal/vertical drive).
Q2 = MAIN SWITCH
S2 = HOOTER PUSH BUTTON
X5 = SOCKET
F8 = PHASE CONTROL LED-
DIODE (INSIDE THE BOX)
E1,E2 = SOCKET FOR HAND TOOLS
S7,S8 = DIRECTION BUTTONS
S1 = EMERGENCY STOP
XS7 = SOCKET FOR GATE
X8 = SOCKET FOR TEST
XS.1 = SPECIAL PLUG
Q2.1 = PHASE INVERTER SWITCH
H3 = CONTROL LAMP “PHASES OK”
-X1
-X3
+OP1
-Q1
0
-Q2.1
-S2
-Q2
-A1
option:
thermostat
-E1/-E2
+OP2
-P1
-X5
-X22
-XS7
-X8
9999h
1
-H3
Option:
drive hour
meter
-S7
-S1
-S8
Telemecanique
-X6
+E3
-WE3 5G1,5 mm2
-X6
+E3
-S6
-S4
-S5
b) for moving the chassis, when it is con-
nected to a socket X3 on the chassis
electric box.