ERECTION AND DISMANTLING
41
SC4000 Pos 4
V23C_09.13
4.6.3 ASSEMBLY OF THE TELESCOPIC EXTENSIONS
See also 2.2.2.
T
he max. width of the telescopic ex tension is 1,4 m.
The assembly of the telescopic ex tension must always be carried out when the plat-
form is in its lowest position.
The assembly of the telescopic ex tension will be carried out as follows:
- The telescopic pipes will be assembled to the required length, the locking
of the telescopic pipe must be severed with the locking pin (item 1 in the
picture).
- The plywood board will be assembled onto the telescopic pipes.
- The fastening of the plywood board will be secured by the fastening plates
and screws and nuts (items 2-5 in the pic ture).
- The railing pipes will be assembled and their fastening will be secured
- the round railing pipes will be fastened with screws and nuts (item 6-7)
- the rectangular railing pipes will be fastened with the railing tting screw
(item 8)
- The railing board will be assembled to the railing pipes. The fastening of the
board will be secured with screws.
NOTE!
THE RAILING BOARD MUST BE USED IN THE RAILINGS.
IN THE ASSEMBLY OF THE TELESCOPIC EXTENSIONS IT IS ALLOWED TO
USE ONLY PARTS AND MATERIAL RECOMMENDED BY THE MANU FAC-
TURER, SEE SECTION 8.
!

Table of Contents