6.3.4. PLATFORM LUBRICATION SCHEDULE
Lubrication Point on Amount of Lubrication Lubrication Grade of
period diagram lubrication point operation lubricant
points
Every30 1 all racksx),pinionsof smearwith graphite
hours of safety brake and brush grease
operation lifting motors (clean,
lubricate)
Every120 2 2+5 gearboxofthelifting checktheoil see
hours of motors level manu fac tures
operation service
instructions
3 1 gearboxofthechassis checktheoilsee
drive unit level manufactures
service
instructions
Every360 4 4 axleoftheoutrigger presswith grease
hours of grease gun
operation
5 5 screw inside the jack press with grease
grease gun
6 5 ball joint of the jack smear with grease
brush
7 4 locking tap for the smear with grease
outrigger brush
8 1 platform lev elling smear with machine oil
device brush
9 1 tow bar smear with grease
brush
10 1 centre joint of the press with grease
control mechanism grease gun
11 all joint of the chassis press with grease
steering mechanism grease gun
x)allnewrackshavetobelubricatedbeforeuse.