OPERATIONAL INSTRUCTIONS
9
SC4000 Pos 5
V23C_09.13
Stopping the platform
- platform stops by releasing the control push-button S4, S5 on the pendant
control device E3 or S7, S8 on the platform electric box OP2
- platform must stop by itself on the bottom- and top-positions through
the limit switches
- use emergency stop S6 on the pendant control device E3 or S1 on the
platform electric box OP2 in emergency situations and the platform
stops immediately
Finishing the work
- when nishing the work the platform has to be lowered to the bottom
position
- disconnect the supply voltage using main switches Q1 and Q2 on the
chassis and the platform electric box
- disconnect the supply cable from the socket X1 of the chassis electric
box and put it to a safety place (Note: The cable is under tension until
the supply cable is disconnected from the wall socket)
0
-Q2.1
-S2
-Q2
-A1
option:
thermostat
-E1/-E2
+OP2
-P1
-X5
-X22
-XS7
-X8
9999h
1
-H3
Option:
drive hour
meter
-S7
-S1
-S8
Telemecanique
-X6
+E3
-WE3 5G1,5 mm2
Q2 = MAIN SWITCH
S2 = HOOTER PUSH BUTTON
X5 = SOCKET
F8 = PHASE CONTROL LED-
DIODE (INSIDE THE BOX)
E1,E2 = SOCKET FOR HAND TOOLS
S7,S8 = DIRECTION BUTTONS
S1 = EMERGENCY STOP
XS7 = SOCKET FOR GATE
X8 = SOCKET FOR TEST
XS.1 = SPECIAL PLUG
Q2.1 = PHASE INVERTER SWITCH
H3 = CONTROL LAMP “PHASES OK”
b) using the pendant control box E3,
- connect the plug of the pendant
control box E3 to the socket X5
-X6
+E3
-S6
-S4
-S5
S4 - PUSH-BUTTON - UP
S5 - PUSH-BUTTON- DOWN
S6 - EMERGENCY STOP
X6 - PLUG
Drawing 5.6 Platform driving control
realised by the pendant control box E3