5.6 Setting the Press-on Pressure of the Transverse Cleaning 25
Figure 5.6 Menu page "400 Target values"
5.6 Setting the Press-on Pressure of the Transverse Cleaning
The pressure of the transverse-cleaning brush to the front or rear edge of the formwork element
can be adjusted via the operating panel (see Figure 5.6, page 25).
In order to apply more pressure to the brush on the front face, the button "+" in the field "Supply
front edge of brushes" must be pushed; less pressure is applied with button "-".
The pressure of the transverse cleaning brush to the rear edge is set in the field below.
The possible setting range is between 0 and 30. The value displayed refers to wear of the
brush.
For a new brush, the value is at “ 0mm”,
for a worn one, it is at “30mm”.
5.7 Setting the pressure pre-tension
The sensor is set ex works and re-adjustment usually is not necessary. Only exchange of the
sensor or a strong mechanical effect on the sensor holder requires subsequent settings. Please
contact our technical support.
5.8 Switching off the machine
After termination of the cleaning work, operate the button "STOP" at the right control cabinet.
Switch off the machine by turning the main switch to the position 0-OFF.
5.9 EMERGENCY OFF button
In case of emergencies, the machine can be stopped at once with the EMERGENCY OFF button.
The EMERGENCY OFF buttons are located at the right and left of the control cabinets and at the
last roller table.