WARNING
Please check the firmness of all the doors and covers before running the analyzer.
Make sure all the safety measurements are adopted. Disabling any safety device or
sensor is prohibited.
Please take action to address any alarm and problem indication immediately.
Do not touch the moving parts.
Contact scil animal care company or scil-authorized distributors if any damaged part is
found.
Be careful when opening/closing and removing/installing the doors, covers and boards of
the analyzer.
Discard the analyzer according to government regulations.
Do not contact the patients’ sample blood directly.
Be sure to dispose of reagents, waste, samples, consumables, etc., according to local
regulations.
The reagents are irritating to eyes, skin and airway. Wear proper personal protective
equipment (e.g., gloves, lab coat, etc.) and follow safe laboratory procedures when
handling them and the contacted areas in the laboratory.
If reagents accidentally spill on your skin or in your eyes, rinse the area with ample
amount of clean water; seek medical attention immediately.
Keep your clothes, hair and hands away from moving parts to avoid injury.
The sample probe tip is sharp and may contain biohazardous materials. Exercise caution
to avoid contact with the probe when working around it.
Before maintaining or servicing the analyzer, its surface or the sample probe and other
parts concerned must be cleaned and sterilized (it is recommended that the parts be
wiped with alcohol of which the concentration is 75%) to avoid biohazards or other
damages.
CAUTION
Please use the analyzer strictly according to this manual.
Please adopt proper measurements to prevent the reagents from being contaminated.
NOTE:
Use the reagents specified by the manufacturer only. Store and use the reagents as
instructed by instructions for use of the reagents.
Check if the reagent tubes are properly connected before using the analyzer.
Class 3B laser:
o Optical density: OD4+
o Radiation exposure level: 56.77 mW/cm
2
o Max. output: 10 mW
o Wavelength: 625 nm
o Standard: IEC 60825-1
o Publication date: 2007.03
o Use goggles when necessary