−32−
4
EnsurethattheMainSWisOFF.
TheACUnitislocatedononesideofMonitorontheBase.TheACUnithasMainSW,Earth
TerminalandtheInletwhichconnectsthePowerCord.
FIG.6.4a ACUNIT
Besuretoindependentlyusethepowersupplysocketoutletequipped
withanEarthLeakageBreaker.Usingapowersupplywithoutan
EarthLeakageBreakercancauseafirewhenelectricleakageoccurs.
Ensurethatthe"accuratelygroundedindoorearthterminal"andthe
earthwireareavailable(exceptinthecasewhereapowercordplug
withearthisused).Thisproductisequippedwiththeearthterminal.
Connecttheearthterminalandtheindoorearthterminalwiththe
preparedcable.Ifthegroundingworkisnotperformedappropriately,
customerscanbesubjectedtoanelectricshock,andtheproduct's
functioningmaynotbestable.<ForTaiwan>
Ensurethatthepowercordandearthwirearenotexposedonthe
surface(passage,etc.).Ifexposed,theycanbecaughtandare
susceptibletodamage.Ifdamaged,thecordandwirecancause
electricshockandshortcircuitaccidents.Ensurethatthewiring
positionisnotinthecustomer'spassagewayorthewiringhas
protectivecovering.
Afterwiringpowercordonthefloor,besuretoprotectthepowercord.
Exposedpowercordissusceptibletodamageandcausesanelectric
shockaccident.
MainSWoff
POWERSUPPLY,ANDEARTHCONNECTION
CIRCUITPROTECTOR
MAINSW
EARTHTERMINAL<ForTaiwan>  
Connectwiththeindoorearthterminal.
INLET
ACCable(PowerCord)
EARTHWIRE<ForTaiwan>