EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series - Configuration 5: Motor potentiometer CCW

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Operation
Binary control
Operating Instructions – MOVIMOT
®
flexible
175
7.2.6 Configuration 5: Motor potentiometer CCW
Fixed setpoint processing mode: Motor potentiometer
(cannot be changed)
Behavior of the drive unit Digital input "DRIVE"
LED
DI01 DI02 DI03 DI04
Left Motor
poten-
tiomete
r up
Motor
poten-
tiometer
down
Reset
The drive unit stops with deceleration setpoint t1.
1)
FCB01 Output stage inhibit is activated afterwards.
0 x x x Lights up
yellow
The drive unit is running in negative direction of rotation
(counterclockwise rotation) with the speed setpoint "Mo-
tor potentiometer".
The acceleration setpoint t1 is active.
1)
1 0 0 x Illuminated
in green
The drive unit is running in negative direction of rotation
(counterclockwise rotation) with the increasing speed
setpoint "Motor potentiometer".
2)
The change in speed is defined by the parameter Accel-
eration of the motor potentiometer function.
1 1 0 x Illuminated
in green
The drive unit is running in negative direction of rotation
(counterclockwise rotation) with the decreasing speed
setpoint "Motor potentiometer".
2)
The change in speed is defined by the parameter Decel-
eration of the motor potentiometer function.
1 0 1 x Illuminated
in green
The drive unit is running in negative direction of rotation
(counterclockwise rotation) with the constant speed
setpoint "Motor potentiometer".
1)
The acceleration setpoint t1 is active.
1)
1 1 1 x Illuminated
in green
The drive unit is in fault state. x x x x Lights up
or flashes
red
The fault state has been reset. 0 0 0 1 Lights up
yellow
1) If potentiometer t1 is deactivated using the parameter settings, the acceleration setpoint 1/ deceleration setpoint 1 of the fixed set-
point processing will be activated.
2) The speed setpoint of the motor potentiometer can only be changed when the drive unit is enabled.
0 = No voltage 1 = 24V x = Any