EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series - Page 208

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Service
Fault/error table
Operating Instructions – MOVIMOT
®
flexible
208
Subfault: 12.3
Description: Temperature
Response: Output stage inhibit
Cause Measure
Brake temperature outside permitted range (too
high or too low).
Check the ambient conditions and the application.
Brake temperature too high. When using decent-
ralized devices, DC link overvoltage is reduced by
the brake.
Check the application for how often generator
mode occurs.
Subfault: 12.4
Description: Brake control module missing
Response: Output stage inhibit
Cause Measure
Brake control has been activated although the
hardware is not equipped with the matching
module.
Select another brake type or brake connection
Subfault: 12.5
Description: Short circuit
Response: Output stage inhibit
Cause Measure
Short circuit in the brake detected. Check the brake connection.
Subfault: 12.6
Description: Wear limit reached
Response: Emergency stop + output stage inhibit
Cause Measure
Brake worn Replace the brake or readjust it
Subfault: 12.10
Description: Digital motor integration fault – critical
Response: Output stage inhibit
Cause Measure
The intelligent brake rectifier of "digital motor in-
tegration" signaled a critical component fault.
See subcomponent fault
29129451/EN – 12/2019