EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series - Page 209

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Service
Fault/error table
Operating Instructions – MOVIMOT
®
flexible
209
8.6.11 Error 13 encoder 1 fault
Subfault: 13.1
Description: Position comparison check
Response: Encoder 1 – latest critical fault
Cause Measure
Faulty comparison between raw position and
track counter of absolute encoders.
– Check the track signal wiring.
– Check interference sources (e.g. from the area
of EMC).
– Replace encoder.
– Replace the card.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
Subfault: 13.2
Description: Unknown encoder type
Response: Encoder 1 – latest critical fault
Cause Measure
Encoder type not known and not supported by
device.
– Check the encoder type.
– Contact SEW‑EURODRIVE Service.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
Subfault: 13.3
Description: Invalid data
Response: Encoder 1 – latest critical fault
Cause Measure
Invalid encoder nameplate data (measuring
steps/pulses per revolution/multi-turn).
– Check the startup parameters.
– Replace encoder.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
29129451/EN – 12/2019

Table of Contents

Related product manuals