EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series - Page 220

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Service
Fault/error table
Operating Instructions – MOVIMOT
®
flexible
220
Subfault: 16.25
Description: User-defined current limit too low for standstill current
Response: Output stage inhibit
Cause Measure
User-defined current limit value too small for min-
imum standstill current.
Increase the user-defined current limit, or disable
the standstill current function.
Subfault: 16.26
Description: Nominal values incomplete or implausible
Response: Output stage inhibit
Cause Measure
During startup using nameplate data: Nominal
voltage, nominal current, nominal speed or nom-
inal torque are not entered or are not plausible.
Enter or check nominal voltage, nominal current,
nominal speed, and nominal torque.
Subfault: 16.27
Description: Maximum current or maximum torque not plausible
Response: Output stage inhibit
Cause Measure
During startup using nameplate data: Maximum
current or maximum torque not entered, or maxi-
mum current and maximum torque not plausible.
Check the maximum current and maximum
torque.
Subfault: 16.30
Description: Faulty EtherCAT
®
EEPROM configuration state
Response: Warning
Cause Measure
Faulty EtherCAT
®
/SBus
PLUS
EEPROM configura-
tion status.
EEPROM not loaded; binary file not loaded.
Contact the SEW‑EURODRIVE Service.
Faulty EEPROM loading procedure. Contact the SEW‑EURODRIVE Service.
Faulty EEPROM checksum. Contact the SEW‑EURODRIVE Service.
Subfault: 16.40
Description: Data of selected motor not valid
Response: Output stage inhibit
Cause Measure
Startup data set on replaceable memory module
not valid for this motor.
Replace the memory module.
29129451/EN – 12/2019