8
Service
Fault/error table
Operating Instructions – MOVIMOT
®
flexible
232
Subfault: 25.19
Description: Control electronics QA data – CRC error
Response: Warning
Cause Measure
Faulty quality assurance data of control electron-
ics.
Contact the SEW‑EURODRIVE Service.
Subfault: 25.20
Description: Initialization error – basic device memory
Response: Output stage inhibit
Cause Measure
Initialization error of the basic device memory. Contact the SEW‑EURODRIVE Service.
Subfault: 25.21
Description: Runtime error – basic device memory
Response: Emergency stop + output stage inhibit
Cause Measure
Runtime error in memory of basic device. Contact the SEW‑EURODRIVE Service.
Subfault: 25.30
Description: Initialization error – replaceable memory module
Response: Output stage inhibit
Cause Measure
The formatting of the replaceable memory
module does not match.
Restore delivery state. NOTICE: All the data on
the replaceable memory module will be reset to
default.
Initialization error of replaceable memory module
after delivery state.
Contact the SEW‑EURODRIVE Service.
Subfault: 25.31
Description: Runtime error – replaceable memory module
Response: Emergency stop + output stage inhibit
Cause Measure
Runtime error of replaceable memory module. Contact the SEW‑EURODRIVE Service.
Subfault: 25.32
Description: Replaceable memory module not compatible
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause Measure
The inserted replaceable memory module cannot
be used.
Replace the memory module.