9
Inspection and maintenance
Inspection and maintenance work
Operating Instructions – MOVIMOT
®
flexible
267
3. NOTICE!Loss of the guaranteed degree of protection. Possible damage to prop-
erty. Make sure not to damage the sealing surfaces when removing the gasket.
Loosen the used gasket by levering it off the retaining cams.
ð Doing so will be easier if you adhere to the sequence shown in the figure be-
low.
30561533323
4. Remove the old gasket completely from the connection box.
30561542155
29129451/EN – 12/2019