AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 136
a-1. Waste toner pipe lock detector
1) Remove the developing unit and the process unit.
2) Remove the OPC drum motor and the developing motor. (See b-
1. OPC drum motor and b-2. Developing motor in this section)
3) Remove the drum drive unit. (See a. Drum drive unit in this sec-
tion)
4) Disconnect the connector, and remove the waste toner pipe lock
detector.
a-2. Process humidity sensor
1) Remove the developing unit. (See a. Developing unit in the
[Developer tank section])
2) Remove the process unit. (See a. Process unit in the [OPC drum
section])
3) Remove the OPC drum motor and the developing motor. (See b-
1. OPC drum motor in this section)
4) Remove the drum drive unit. (See a. Drum drive unit in this sec-
tion)
5) Remove the drum earth plate. Remove the set screw and the fly-
wheel joint. Remove the E-ring.
6) Disconnect the connector, and remove the drum drive frame.
7) Remove the parts.
8) Disconnect the connector, and remove the sensor plate.
9) Remove the process humidity sensor.
b-1. OPC drum motor
b-2. Developing motor
1) Remove the rear cabinet.
1
1
1