: Feb. 6 2004
1
AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 152
a-3. Power cooling fan motor 1
a-4. Power cooling fan motor 2
1) Remove the rear cabinet. (See a-1. AC power PWB in this sec-
tion)
2) Disconnect the connector, and remove the AC power PWB
unit.(See a-1. AC power PWB in this section)
3) Disconnect the connector and remove the harness clamp. Remove
the power cooling fan motors 1/2.
a-5. Dehumidifier heater relay PWB
1) Remove the rear cabinet. (See a-1. AC power PWB in this sec-
tion)
2) Disconnect the connector and remove the supporter. Remove the
dehumidifier heater relay PWB.
3) Remove the AC/DC power unit.
4) Remove the AC power PWB unit.
5) Remove the DC power PWB unit.
1
NOTE: When assembling, fit the mark with the fan rotating direction
(label on the back surface).
Fan blowing direction
Mark
Mark
REVERSE