AR-M550/M620/M700 SELF DIAG MESSAGE AND TROUBLESHOOTING 9 - 9
Main
code
Sub
code
Title
The entered account name of the
POP3 server or the password for
authentication is invalid.
CE 07 Phenomenon Display Lamp
Message
Details The entered account
name of the POP3 server
or the password for
authentication is invalid.
POP3 server
authentication check
error
Section
Operation
mode
Note
Case 1 Trouble
position/
Cause
Improper connection of
the network cable
Remedy Check connection of the
network cable.
Note
Case 2 Trouble
position/
Cause
Improper account name
or password registered in
the POP3 server
Remedy Check that the account
name or the password
registered for the POP3
server is correct.
Note
Main
code
Sub
code
Title
The specified mail server (POP3)
suspends response.
CE 08 Phenomenon Display Lamp
Message
Details The specified mail server
(POP3) suspends
response.
POP3 server time-out
error
Section
Operation
mode
Note
Case 1 Trouble
position/
Cause
Improper connection of
the network cable
Remedy Check connection of the
network cable.
Note
Case 2 Trouble
position/
Cause
Remedy An error occurs in the
POP3 server.
Note Check for any error in the
POP3 server.
Main
code
Sub
code
Title
CIS shading trouble (White
correction)
E6 11 Phenomenon Display Lamp
Message
Details CIS shading trouble
(White correction)
When the power is
turned on or when the
proper gain setup value
is not obtained with SIM
63-2 CIS shading (Retry
number: 256 times):
CIS white reference plate
scan level is abnormal
when the lamp is lighted.
Section Scanner
Operation
mode
Note
Case 1 Trouble
position/
Cause
Defective installation of
the harness to the CIS
unit
CIS unit abnormality
Remedy CIS unit harness check
Note
Case 2 Trouble
position/
Cause
Reference white plate
dirt
Remedy Clean the reference
white plate.
Note
Case 3 Trouble
position/
Cause
CIS lighting trouble
Remedy Use SIM 5-3 to check the
light quantity of CIS.
Note
Case 4 Trouble
position/
Cause
Scanner PWB
abnormality
Remedy Scanner PWB check
Note
Main
code
Sub
code
Title
CIS communication trouble
E6 14 Phenomenon Display Lamp
Message
Details CIS communication
trouble
When an error occurs in
an access check to the
CIS-ASIC on turning on
the power or closing the
DSFP cover. (Retry
number: 5 times)
Communication trouble
between the scanner
PWB and the CIS-ASIC.
(Clock synchronization)
Section Scanner
Operation
mode
Note