template:Standard_CN.dot; filename: Shini product repair manual; Printdate: 8/1/2014 1:58:00 PM; savedate: 8/1/2014 1:58:00 PM
heat abnormally and premature failure.
For example, a heating pipe is designed as 380v and 12kw, its actual resistance is
12Ω. If the heating pipe is used for 230V (the same wiring), its actual power is about
4.4kw,much lower than the nominal value of 12kw. If the heating pipe is used for
460v(the same wiring),its actual power is about 17.6kw,much higher than the nominal
value of 12kw.